Malfunction code

Main Unit Field Service

4-24

IV

T

roub

lshoo

t

in

g

2.4.24

C050: Hard disk access error (Only for magicolor 5450)

2.4.25

C051: Hard disk full error (Only for magicolor 5450)

Relevant Electrical Parts

Print Control Board (PWB-P)

Hard disk unit (HDD)

Step

Action

WIRING DIAGRAM

Control Signal

Location

(Electrical

Component)

1

Turn OFF the Power Switch of the printer and
turn it ON again (Restart of the printer.)

-

-

2

Check the HDD connector for proper connection
and correct as necessary.

-

-

3

Check the PWB-P connector for proper connec-
tion and correct as necessary.

-

-

4

Change HDD.

-

-

5

Change PWB-P.

-

-

Relevant Electrical Parts

Print Control Board (PWB-P)

Hard disk unit (HDD)

Step

Action

WIRING DIAGRAM

Control Signal

Location

(Electrical

Component)

1

Turn OFF the Power Switch of the printer and
turn it ON again (Restart of the printer.)

-

-

2

Delete the job hold in “PROOF/PRINT MENU” to
increase the available range for user space.

-

-

3

Check the HDD connector for proper connection
and correct as necessary.

-

-

4

Format HDD with “SYS DEFAULT MENU/HDD
FORMAT.”

-

-

5

Change HDD.

-

-