Main Unit Field Service Miscellaneous Malfunctions (Only for magicolor 5430 DL/5440 DL)

4-29

IV

T

roub

lshoo

t

in

g

4.

Miscellaneous Malfunctions
(Only for magicolor 5430 DL/5440 DL)

4.1

List of Miscellaneous Malfunctions

4.2

ILLEGAL ERROR DUPLEX

Message

Description

ILLEGAL ERROR
DUPLEX

• The Duplex Option is not installed.
• A 2-sided print cycle is run using the type and size of media that are not good

for 2-sided printing.

ERROR
AIDC SENSOR

• The AIDC Sensor has developed a malfunction.

ERROR
COMMUNICATION

• A communications error has occurred in USB or Ethernet interface.

ERROR
ENGINE INTERFACE

• There is a connection failure between the Mechanical Control Board (PWB-

A) and Print Control Board (PWB-P).

ERROR
RAM

• A RAM read or write error has occurred.

ERROR
DIMM

• An SDRAM DIMM error has been detected.

ERROR
ROM

• A control ROM error has been detected.

ERROR
CONTROLLER

• A control error has occurred in the printer.

Relevant Electrical Parts

Duplex Board (PWB-E DU)

Mechanical Control Board (PWB-A)
Print Control Board (PWB-PÅj

Step

Action

WIRING DIAGRAM

Control Signal

Location

(Electrical

Component)

1

Check the printer driver settings.

-

-

2

Check the PWB-E DU connector for proper con-
nection and correct as necessary.

-

-

3

Check the PWB-A connector for proper connec-
tion and correct as necessary.

-

-

4

Check the PWB-P connector for proper connec-
tion and correct as necessary.

-

-

5

Change PWB-E DU.

-

-

6

Change PWB-P.

-

-

7

Change PWB-A.

-

-

5450_E.book_PDF.book 29 ページ 2005年4月12日 火曜日 午後12時54分