6 004ch: ozone ventilation fan motor malfunction, 7 004eh: lv cooling fan motor malfunction, 004ch: ozone ventilation fan motor malfunction -18 – Konica Minolta Magicolor 5440 DL User Manual

Page 205: 004eh: lv cooling fan motor malfunction -18

Advertising
background image

Malfunction code

Main Unit Field Service

4-18

IV

T

roub

lshoo

t

in

g

2.4.6

004CH: Ozone Ventilation Fan Motor malfunction

2.4.7

004EH: LV Cooling Fan Motor malfunction

Relevant Electrical Parts

Ozone Ventilation Fan Motor (M12)

Mechanical Control Board (PWB-A)

Step

Action

WIRING DIAGRAM

Control Signal

Location

(Electrical

Component)

1

Check the M12 connector for proper connection
and correct as necessary.

-

-

2

Check the fan for possible overload and correct
as necessary.

-

-

3

M12 operation check

PWB-A PJ6A-7 (LOCK)

PWB-A PJ6A-5 (ON)

14-I

4

Change PWB-A.

-

-

Relevant Electrical Parts

LV Cooling Fan Motor (M10)

Mechanical Control Board (PWB-A)

Step

Action

WIRING DIAGRAM

Control Signal

Location

(Electrical

Component)

1

Check the M10 connector for proper connection
and correct as necessary.

-

-

2

Check the fan for possible overload and correct
as necessary.

-

-

3

M10 operation check

PWB-A PJ9A-3 (LOCK)

PWB-A PJ9A-1 (ON)

12-J

4

Change PWB-A.

-

-

5450_E.book_PDF.book 18 ページ 2005年4月12日 火曜日 午後12時54分