3 replacing the fusing unit, Replacing the fusing unit -19 – Konica Minolta Magicolor 5440 DL User Manual

Page 56

Advertising
background image

Main Unit Field Service

Periodic Check

2-19

II Main

tena

nce

1.6.3

Replacing the Fusing Unit

NOTE
• Before replacing the Fusing Unit, make sure that it has sufficiently cooled down.

1.

Turn OFF the Power Switch, unplug the power cord from the power outlet, and let the
machine to stand idle for about 20 min.

2.

Open the Front Door.

3.

Remove the Upper Front Cover.

2-30

4.

Disconnect the four connectors [1].
(magicolor 5430 DL/5440 DL)

5.

Disconnect the five connectors [1].
(magicolor 5450)

6.

Open the Right Door.

7.

Remove two screws [2] and the Fus-
ing Unit.

8.

Install the new Fusing Unit.

9.

From the SERVICE mode, select
RESET COUNTER FUSER UNIT.
Then, execute this function to reset
the Fusing Unit counter value.
(magicolor 5430 DL/5440 DL)

☞ For details, see “III. Adjustment/

Setting.”

10. From the Menu, select QUALITY

MENU

→ SUPPLIES → REPLACE

→ FUSER UNIT. Then, execute this
function to reset the Fusing Unit
counter value. (magicolor 5450)

☞ For details, see “III. Adjustment/

Setting.”

[1]

4138fs2003c1

[2]

[3]

4138fs2004c1

5450_E.book_PDF.book 19 ページ 2005年4月12日 火曜日 午後12時54分

Advertising