Main Unit Field Service

Other

2-53

II Main

tena

nce

9.

Snap off the C-clip [8], and remove
the bearing [9] and the Pressure/
Retraction Clutch/2nd Image Trans-
fer [10].

Precautions for Reinstallation
• When reinstalling the bearing and

Pressure/Retraction Clutch/2nd
Image Transfer, make sure that the
protrusion [11] on the Pressure/
Retraction Clutch/2nd Image Trans-
fer fits into the locking slot [12].

4.4.30

Pressure/Retraction Clutch /1st Image Transfer (CL4)

1.

Remove PWB Box/1.

2-47
2.

Remove PWB Box/2

2-48
3.

Disconnect the connector [1],
remove three screws [2], and pull out
the Pressure/Retraction Clutch/1st
Image Transfer Assy [3].

4.

Snap off the E-ring [4], and remove
the bearing [5] and the Pressure/
Retraction Clutch/1st Image Trans-
fer [6].

[10]

[11]

[12]

[9]

[8]

[7]

4138fs2536c1

[1]

[2]

[3]

4138fs2040c0

[4]

[5]

[6]

4138fs2041c0