Ii maintenance, Periodic check, 1 service schedule – Konica Minolta Magicolor 5440 DL User Manual

Page 38: Maintenance, Periodic check -1, Service schedule -1

Advertising
background image

Main Unit Field Service

Periodic Check

2-1

II Main

tena

nce

II Maintenance

1.

Periodic Check

NOTE
• Be sure to note that the feed trays are named differently depending upon the

printer model.

• The following procedures use the magicolor 5430 DL/5440 DL tray names.

1.1

Service schedule

Guaranteed period (5 years or 400,000 prints)

magicolor 5430 DL / 5440 DL

magicolor 5450

MANUAL FEED TRAY

TRAY 1

TRAY 1

TRAY 2

TRAY 2

TRAY 3

TRAY 3

TRAY 4

Per cycle

× number of prints

× 10,000 prints

Number
of times

20

30

40

Main Unit

Upon each call
(200,000)

2

300,000

1

Lower Feeder Unit

300,000

1

5450_E.book_PDF.book 1 ページ 2005年4月12日 火曜日 午後12時54分