Mechanical adjustment, 1 registration adjustment, Mechanical adjustment -2 – Konica Minolta Magicolor 5440 DL User Manual

Page 260: Registration adjustment -2

Advertising
background image

Mechanical Adjustment

Lower Feeder Unit Field Service Ver. 2.0 April 2005

3-2

III

Ad

just

men

t/Set

ting

2.

Mechanical Adjustment

2.1

Registration adjustment

This adjustment must be made if:
• The printed image deviates in the CD direction.

1.

Remove the tray.

2.

Loosen two screws [1].

3.

Loosen two screws [2].

4.

Watching the graduations [3] on the
adjusting plate, move the Edge
Guide Plate [4] as necessary.

Adjustment range:

±

2.0 mm

5.

Tighten the four screws that have
been loosened and mount the tray.

[1]

4537fs3501c0

[2]

[2]

4537fs3502c0

[3]

[4]

5450_E.book_PDF.book 2 ページ 2005年4月12日 火曜日 午後12時54分