Konica Minolta Magicolor 5440 DL User Manual

Page 200

Advertising
background image

Main Unit Field Service

Malfunction code

4-13

IV

T

roub

lshoo

t

in

g

004E

POWER

FAN

LV Cooling Fan Motor
malfunction

• The Motor Lock signal remains HIGH for a given

period of consecutive time while the LV Cooling
Fan Motor is being rotated.

0060

FUSER

MOTOR

Fusing Motor malfunc-
tion

• The Fusing Motor does not rotate evenly even

after the lapse of a given period of time while it is
being started.

• The Motor Lock signal remains HIGH for a given

period of consecutive time while the Fusing
Motor is being rotated.

0094

XFER

DETACH 2

2nd image transfer
pressure / retraction
failure

• The Retraction Position Sensor/2nd Image

Transfer is not activated (retracted position)
within a given period of time after the retraction
sequence of the 2nd Transfer Roller has been
started.

• The Retraction Position Sensor/2nd Image

Transfer is not deactivated (pressed position)
within a given period of time after the pressure
sequence of the 2nd Transfer Roller has been
started.

0096

XFER

DETACH 1

1st image transfer
pressure / retraction
failure

• The Retraction Position Sensor/1st Image Trans-

fer is not activated (retracted position) within a
given period of time after the Intermediate Trans-
port Motor has started rotating.

• The Retraction Position Sensor/1st Image Trans-

fer is not deactivated (pressed position) within a
given period of time after the Intermediate Trans-
port Motor has started rotating.

0300

POLYGON

MOTOR

Polygon Motor mal-
function

• The Polygon Motor does not rotate evenly even

after the lapse of a given period of time after it
has been started.

• The Motor Lock signal remains HIGH for a given

period of consecutive time while the Polygon
Motor is being rotated.

0310

LASER

ERROR

Laser malfunction

• The SOS signal is not detected within a given

period of time after the output of the laser has
been started.

0500

FUSER

ERROR

Heating Roller warm-
up failure

• The Heating Roller Thermistor does not detect

the specified temperature and the warm-up cycle
is not completed even after the lapse of a given
period of time after the cycle has been started.

0501

FUSER

ERROR

Fusing Pressure Roller
warm-up failure

• The Fusing Pressure Roller Thermistor does not

detect the specified temperature and the warm-
up cycle is not completed even after the lapse of
a given period of time after the cycle has been
started.

0510

FUSER

ERROR

Abnormally low Heat-
ing Roller temperature

• The temperature detected by the Heating Roller

Thermistor remains lower than the specified
value for a given period of time or longer.

LCD1

(Service

call ID)

LCD2/LCD3

(Error

description)

Item

Detection Timing

5450_E.book_PDF.book 13 ページ 2005年4月12日 火曜日 午後12時54分

Advertising