2 parts to be replaced by a service engineer (fru), 3 maintenance parts, Maintenance parts -3 – Konica Minolta Magicolor 5440 DL User Manual

Page 40

Advertising
background image

Main Unit Field Service

Periodic Check

2-3

II Main

tena

nce

1.2.2

Parts to be Replaced by a Service Engineer (FRU)

* : Continuous printing
** : 2 pages/job

1.3

Maintenance parts

• To ensure that the machine produces good prints and to extend its service life, it is rec-

ommended that the maintenance jobs described in this schedule be carried out as
instructed.

• Replace with reference to the numeric values displayed on the Life counter.
• Maintenance conditions are based on A4 or Letter, Standard mode and Preheat OFF.

A. Main Unit

* : Continuous printing
** : 2 pages/job

No

Class

Part to be replaced

Number of

prints

Clean Replace

Description

1

Fusing

section

Fusing Unit

150,000

(MP *)

130,000

(2P/J

**

)

2

Tray 1/

Media feed

section

Feed Roller

300,000

3

Manual Feed

section

(magicolor

5440 DL/5450

only)

Feed Roller

300,000

4

Lower Feeder

Unit

Feed Roller

300,000

No

Class

Maintenance parts

Clean

Replace

Description

Ref.Page

in this

manual

1

Tray 1

Feed Roller

When neces-

sary to prevent

media jams

300,000

2-6

2

Manual
Feed Tray
(magicolor
5440 DL/
5450 only)

Feed Roller

When neces-

sary to prevent

media jams

300,000

2-7

3

Fusing
section

Fusing Unit

-

150,000

(MP *)

2-19

130,000

(2P/J

**

)

5450_E.book_PDF.book 3 ページ 2005年4月12日 火曜日 午後12時54分