Ii maintenance, Periodic check, 1 maintenance procedure (periodic parts check) – Konica Minolta Magicolor 5440 DL User Manual
Page 251: 1 feed roller, Maintenance, Periodic check -1, Maintenance procedure (periodic parts check) -1, Feed roller -1
Advertising
Lower Feeder Unit Field Service Ver. 2.0 April 2005
Periodic check
2-1
II Main
tena
nce
II Maintenance
1.
Periodic check
1.1
Maintenance procedure (Periodic parts check)
NOTE
• The alcohol used in this cleaning procedure is isopropyl alcohol.
1.1.1
Feed Roller
A. Cleaning procedure
1.
Open the Lower Feeder Unit Right
Cover.
2.
Wipe the Feed Roller [1] clean of dirt
using a soft cloth dampened with
alcohol.
B. Replacing procedure
1.
Slide out Tray 1.
2.
Lock the Paper Lift Plate.
3.
Snap off two C-clips [1] and the bear-
ing [2] at the front.
4.
Snap off the C-clip [3] and remove
the Feed Roller [4].
4537fs2501c0
[1]
[1]
[2]
4537fs2012c0
[3]
[4]
4537fs2013c0
5450_E.book_PDF.book 1 ページ 2005年4月12日 火曜日 午後12時54分