Lower Feeder Unit Field Service Ver. 2.0 April 2005

Periodic check

2-1

II Main

tena

nce

II Maintenance

1.

Periodic check

1.1

Maintenance procedure (Periodic parts check)

NOTE
• The alcohol used in this cleaning procedure is isopropyl alcohol.

1.1.1

Feed Roller

A. Cleaning procedure
1.

Open the Lower Feeder Unit Right
Cover.

2.

Wipe the Feed Roller [1] clean of dirt
using a soft cloth dampened with
alcohol.

B. Replacing procedure
1.

Slide out Tray 1.

2.

Lock the Paper Lift Plate.

3.

Snap off two C-clips [1] and the bear-
ing [2] at the front.

4.

Snap off the C-clip [3] and remove
the Feed Roller [4].

4537fs2501c0

[1]

[1]

[2]

4537fs2012c0

[3]

[4]

4537fs2013c0

5450_E.book_PDF.book 1 ページ 2005年4月12日 火曜日 午後12時54分