Mfs parameters -128 – PIONEERPOS AT Commands G24-LC User Manual
Page 192
Network
3-128
G24-L AT Commands Reference Manual
April 15, 2008
The following table shows the +MFS parameters.
Example
AT+MFS=?
//Test command
+MFS: (0-3),(0,1)
OK
AT+MFS?
//Read command
+MFS: 1,0
OK
AT+MFS=3
//Set only Frequency of search
OK
AT+MFS?
+MFS: 3,0
OK
AT+MFS=2,1
//Set Frequency of search and search mode.
OK
AT+MFS?
+MFS: 2,1
//POWER CYCLE phone
AT+MFS?
//Previous values restored after power up.
+MFS: 2,1
OK
AT+MFS=0
OK
AT+MFS?
+MFS: 0,1
OK
Table 3-80: +MFS Parameters
<Parameter>
Description
<freq>
This value defines the frequency of search.
0
Continuous. Minimum interval between subsequent search attempts is 1
second.
1
Medium. Minimum interval between subsequent search attempts is 10
seconds.
2
Slow. Minimum interval between subsequent search attempts is 30 seconds.
3
Fast. Minimum interval between subsequent search attempts is 5 seconds.
The default value is 1, before it was changed for the first time.
<mode>
This value defines the search mode. The mode defines whether network selection and
registration are performed automatically by the G24-L, or whether the selection is
forced to the specific operator to which the G24-L is registered to at a given moment.
0 Automatic
1 Manual
The default value is 0, before it was changed for the first time.