Clck, facility lock, Clck, facility lock -184, Clck, facility lock” on – PIONEERPOS AT Commands G24-LC User Manual
Page 248: Er to, Clck, Sim pin2
Access
3-184
G24-L AT Commands Reference Manual
April 15, 2008
Example
AT+CPWD =?
+CPWD: ("SC",8),("AO",4),("OI",4),("OX",4),("AI",4),("IR",4),("AB",4),("AG",4), ("AC",4),("P2",8)
OK
AT+CPWD?
+CME ERROR: operation not supported
AT+CLCK: "sc",1,"current pin password"
AT+CPWD="sc","incorrect old password","new password"
+CME ERROR: incorrect password
AT+CLCK="sc",2
+CLCK: 0
OK
AT+CPWD="sc","old password","new password"
+CME ERROR: operation not allowed
AT+CLCK="fd",1,"current pin2 password"
AT+CPWD="p2","old password","new password"
OK
AT+CLCK="ai",2
+CLCK: 0,1
+CLCK: 0,2
+CLCK: 0,4
OK
AT+CLCK="ai",1,"correct password"
OK
AT+CLCK="ai",2
+CLCK: 1,1
+CLCK: 1,2
+CLCK: 1,4
OK
AT+CPWD="ai","old password","new password"
OK
+CLCK, Facility Lock
This command locks, unlocks or interrogates a G24-L or a network facility <fac> (any kind of
call barring program). A password is mandatory for performing locking and unlocking actions,
but not for querying. The features of the G24-L that are affected by this are the keypad power-up
operation and fixed dialing list. When querying the status of a single call barring program
<mode>=2, the <status> for each call type will be returned.
For <fac>="SC", SIM Card PIN setting and for <fac>="FD", SIM Fixed Dialing memory setting,
(For more information about <class>, refer to
showing the +CLCK parameters).
The <passwd> for "SC" is SIM PIN, and for "FD" it is SIM PIN2.
Note:
Concerning <fac>="FD". When FD is enabled it is possible to make a call only to
numbers that are located in the FD phone book, include GPRS session (#99*). If the
number is not in the phone book the user will receive "operation not allowed". In order to
insert a new number to the FD phone book, the user must disable the FD feature first
<mode>=0 , insert the new number and only than enable the FD feature <mode>=1.