The following table shows the +MTDTR parameters.

Example

AT+MTDTR?

+MTDTR:1

OK

AT+MTDTR

+MTDTR:1

OK

AT+MTDTR=?

OK

+MTCTS, CTS Line Test Command

This command sets the CTS pin of the RS232 to active high, waits one second and then returns
the CTS to active low.

Example

AT+MTCTS

OK

&K, RTS/CTS Flow Control

This command configures the flow control. The RTS (Request To Send) is an input line. The RTS
signal is received from the terminal and a low condition indicates that the G24-L can send more
data. The CTS (Clear To Send) is an output line. The CTS signal is sent to the terminal and a low
state indicates that more data can be sent to the G24-L.

The RTS and CTS together make up what is called RTS/CTS or “hardware” flow control. Both
lines are used when “hardware flow control” is enabled in both the terminal and the G24-L
devices. When the terminal is ready and able to receive data, it puts the RTS line in an active
(low) condition to indicate this to the G24-L. If the terminal is not able to receive data (typically
because its receive buffer is almost full), it puts the RTS line in an inactive (high) condition as a
signal to the G24-L to stop sending data. When the terminal is ready to receive more data (for
example, after data has been removed from its receive buffer), it places this line back in the active

Table 3-86: +MTDTR Parameters