The following table shows the +MMAD parameters.

Unsolicited
Messages

AT+MMAD=<Conver

ter_number>

Case:

*. Average calculation

isn't active :

*. Average calculation

is active:

+MMAD:

<Converter_number>,

<Converted_Value> OK

+MMAD:

<Converter_number>, <Average>

OK

If <Report> value is - 3,
the report will be generated
according to report interval
value. If <Report interval>
value was not set, there
will be no messages, but
you can ask for a solicited
message.

Command

Type

Syntax

Response/Action

Remarks

Table 3-98: +MMAD Parameters

<Parameter>

Description

Range/Remark

<Converter
Number>

1-5 Select the A2D converter.

<Report>

0

Unsolicited report is not active/ stop unsolicited report &

deactivate +MMAD operation.
1

Unsolicited report in active for all A2D conversion events.

2

Unsolicited reports are active only for out off boundaries events.

3

"Average report" - send periodic average.

Optional for Average
calculation.

<Rate>

1-255 Select the time interval between two samples.
Units:
100 milli Sec - in case of average computation.
Seconds - in case of A/D sampling only.

100mili - for average;
sec-Otherwise.
Mandatory for Average
calculation.

<low>,<High>

0,230 or 300,450 A decimal value represents the digital value.

Low - The lowest boundary level of digital value.
High - The Highest boundary level of digital value.
Default value for converters 1-3 is 0,230.
Default value for converter 5 is 300,450.

<Converted
Value>

A decimal value represents the returned digital value.
For converters 1-3 and 5, the returned value represent the input level
multiplied by 100.

<Num_of_sam
ples>

2 - 255 The number of samples that are used for average calculation.

Mandatory for Average
calculation.

<Average_calc
_duration>

1 - 255 For how long the average calculation will be active.
0 - Not active.
255 - Endless.
1...254 - minutes.

1- Default value if average is
active.
While not active = 0.