Cbst parameters -32 – PIONEERPOS AT Commands G24-LC User Manual

Page 96

Advertising
background image

Call Control

3-32

G24-L AT Commands Reference Manual

April 15, 2008

The following table shows the +CBST parameters.

Example

AT+CBST=?

+CBST: (000,004,006,007,014,068,070,071,075),(000-001),(000-003)

OK

AT+CBST?

+CBST: 007,000,001

OK

AT+CBST=6

OK

AT+CBST?

+CBST: 006,000,001

OK

Read

AT+CBST?

+CBST:

<speed>,<name>,<ce>

OK

Test

AT+CBST=?

+CBST: (list of

supported
<speed>s),(list of
supported
<name>s),(list of
supported <ce>s)
OK

The Test command returns values
supported by the MA as compound
values.

Table 3-14: +CBST Parameters

<Parameter>

Description

<speed>

0 - Auto-bauding (automatic selection of the speed; this setting is possible in case of
3.1 kHz modem and non-transparent service)
6 - 4800 bps (V.32)
7 - 9600 bps (V.32)
14 - 14400 bps (V.34)
68 - 2400 bps (V.110 or X.31 flag stuffing)
70 - 4800 bps (V.110 or X.31 flag stuffing)
71 - 9600 bps (V.110 or X.31 flag stuffing)
75 - 14400 bps (V.110 or X.31 flag stuffing)
The default value is 7.

Note:

Currently the G24-L supports:
2 baud rates: 4800 and 9600 bps
2 protocols: V.110 and V.32

<name>

0 - Data circuit asynchronous (UDI or 3.1 kHz modem)
1 - Data circuit synchronous (UDI or 3.1 kHz modem)
The default value is 0.

<ce>

0 - Transparent (Reserved for future implementation)
1 - Non-transparent (default)

Command

Type

Syntax

Response/Action

Remarks

Advertising