S96, echo canceling, S96, echo canceling -162, S94 parameters -162 – PIONEERPOS AT Commands G24-LC User Manual

Page 226: Ats96 and ats94 behavior -162

Advertising
background image

Audio

3-162

G24-L AT Commands Reference Manual

April 15, 2008

The following table shows the S94 parameters.

Example

ATS94=0

//Disable sidetone

OK

ATS94=2

+CME ERROR: <err>

ATS94?

000

//Sidetone disabled

OK

S96, Echo Canceling

This command suppresses a large amount of the output sound picked up by the input device
(cancels all echo). S96 value is saved in the Flex.

The following table explains the use of the ATS96 set.

Table 3-105: S94 Parameters

<Parameter>

Description

<n>

0

Disable sidetone

1

Enable sidetone

On power up the sidetone is enabled.

Table 3-106: ATS96 and ATS94 Behavior

ATS96

ATS94

Echo Cancel

Noise Suppress

ST

0

0

Disabled

Disabled

Disabled

0

1

Disabled

Disabled

Enabled

1

0

Enabled

Enabled

Disabled

1

1

Enabled

Enabled

Disabled

Command Type

Syntax

Response/Action

Remarks

Set

ATS96=<n>

OK

or:

+CME ERROR: <err>

The Set command sets the echo
canceling and noise suppression status.

Read

ATS96?

<000-disabled,

001-enabled>

OK

or:

+CME ERROR: <err>

The Read command returns the echo
canceling and noise suppression status.

Test

ATS96=?

+CME ERROR: <err>

Advertising