Mpcmc parameters -154 – PIONEERPOS AT Commands G24-LC User Manual

Page 218

Advertising
background image

Hardware Information

3-154

G24-L AT Commands Reference Manual

April 15, 2008

The following table shows the +MPCMC parameters.

Example

AT+MPCMC=?

+MPCMC:(0-1)

OK

AT+MPCMC=1

OK

AT+MPCMC?

+MPCMC: 1

OK

AT+MPCMC=0

OK

AT+MPCMC?

+MPCMC: 0

OK

Command

Type

Syntax

Response/Action

Remarks

Set

+MPCMC=<flag>

OK

or:

+CME ERROR: <err>

The Set command is used for setting
the PCM clock configuration.

Read

+MPCMC?

+MPCMC: <flag>

OK

or:

+CME ERROR: <err>

The Read command returns the current
PCM clock <flag> value.

Test

+MPCMC=?

+MPCMC: (list of

supported <flag>s)

OK

The Test command returns the possible
<flag> values.

Table 3-99: +MPCMC Parameters

<Parameter>

Description

<flag>

0

Non-continuous PCM clock.

1

Continuous PCM clock.

Before the AT+MPCMC command is set for the first time,
this value is 0.
Power-up is according to the flex.

Advertising
This manual is related to the following products: