Mbc, battery charger, Mbc, battery charger -130 – PIONEERPOS AT Commands G24-LC User Manual

Page 194

Advertising
background image

Hardware Information

3-130

G24-L AT Commands Reference Manual

April 15, 2008

OK

+MBC, Battery Charger

This command allows the battery charger to be managed (start, stop or automatic manage) and get
indication for the battery level (solicited or unsolicited reports).

The Battery is external to the G24-L and connected via the 70 pin connector.

The values of the battery are: 3.2V-4.2V divided to 5 battery levels.

Notes:

• When the battery level is below the minimum, the G24-L will not power up untill the

pre-chargelevel reaches the minimum level for activation.

• The G24-L will manage the charging process and algorithm when charging is enabled.

• The unsolicited reports will appear in the following cases (in case <Ind=1>):

1.

Each time the level of the battery changes.

2.

Inside the limits (3.2 and 4.2).

3.

Charger connected/disconnected.

• The unsolicited report will appear even if the charger cable is not connected (only in

case of <Ind=1>).

• ERRORS: Trying to start a charging process without a battery, error message of: NO

BATTERY DETECTION will be received, for any other problems the following will
be received: ERROR IN CHARGING PROCESS.

Command

Type

Syntax

Response/Action

Remarks

Set

AT+MBC=<Mode>,<

Ind >

OK

or:

+CME ERROR: <err>

The Set command sets the different
mode (start, stop or automatic) and
sets the report to be solicited or
unsolicited.

Read

AT+MBC?

+MBC:

<Status>,<Batterylevel
>,<Mode>,<Ind>

OK

The Read command returns the current
status, battery level, mode and
indication.

Test

AT+MBC=?

+MBC: (List of

supported Mode),(List
of supported
Indication)

OK

The Test command returns the list of
supported modes and indications.

Advertising