Clck parameters -185 – PIONEERPOS AT Commands G24-LC User Manual

Page 249

Advertising
background image

Chapter 3: AT Commands Reference

April 15, 2008

G24-L AT Commands Reference Manual

3-185

The following table shows the +CLCK parameters.

Command

Type

Syntax

Response/Action

Remarks

Set

+CLCK=<fac>,<mode>

[,<passwd>
[,<classx>]]

For <fac> where

<class> is irrelevant
(SC, FD):

+CLCK=<fac>,2

+CLCK: <status>

For <fac> with several

supported <class>es:

+CLCK=<fac>,2

+CLCK:

<status>,<class1>

[<CR><LF>+CLCK:

<status>,<class2>

[…]]

OK

The Set command performs the
specified <mode> action on the
specified <fac>.

Read

+CLCK?

+CLCK: ERROR

Test

+CLCK=?

+CLCK: (list of
supported <fac>s)

The Test command returns the list of
supported facilities.

Table 3-124: +CLCK Parameters

<Parameter>

Description

<fac>

SC

SIM Card PIN setting
<mode>0 Disable PIN

1 Enable PIN)

FD

SIM Fixed Dialing memory setting
<mode>0 Disable fixed dialing feature

1 Enable fixed dialing feature)

AO

BAOC (Bar All Outgoing Calls)

OI

BOIC (Bar Outgoing International Calls)

OX

BOIC-exHC (Bar Outgoing International Calls except to Home Country)

AI

BAIC (Bar All Incoming Calls)

IR

BIC-Roam (Bar Incoming Calls when Roaming outside the home country)

AB

All Barring services (applicable only for <mode>=0)

AG

All outgoing barring services (applicable only for <mode>=0)

AC

All incoming barring services (applicable only for <mode>=0)

<passwd>

String type, 4-8 character password

<mode>

0

Unlock

1

Lock

2

Query status (<passwd> does not apply)

Advertising
This manual is related to the following products: