Note:

If <ppu> contains a dot, a maximum of three digits may appear after the dot, otherwise
an error is generated. For example, if <ppu>=0.61, the Read command displays 0.610.
<ppu>=1.2345 terminates in an error.

If <ppu> does not contain a dot, the number is divided by 1000. For example, if <ppu>=1,
the Read command displays 0.001.

Due to storage constraints, the <ppu> value is limited to a range of 0 to 4095. Values
beyond this range may result in rounding errors. For example, if <ppu>=4095, the Read
command displays 4.095. However, if <ppu>=4096, the Read command displays 4.090
(the last digit is replaced by 0). If <ppu>=456789, the Read command displays 456.000.

+CR, Service Reporting Control

This command controls whether or not the extended format of an outgoing call is displayed or
not. The +CR indication is sent from the G24-L to the terminal whenever a data call is initiated by
the G24-L.

The following table shows the +CR parameters.

Example

AT+CR=1

//Enable reporting

OK

ATD1234567890

+CR: REL ASYNC

Command Type

Syntax

Response/Action

Remarks

Set

+CR=[<mode>]

OK

The Set command enables/disables the
extended format of an outgoing data
call. When enabled, the outgoing data
call is indicated to the terminal through
the unsolicited result code
+CR:<serv>. When the command is
disabled, no +CR is sent to the
terminal.

Read

+CR?

+CR:<mode>

The Read command displays the
current service reporting control
setting.

Test

+CR=?

+CR:<mode>

The Test command displays the list of
supported CR modes.

Table 3-25: +CR Parameters

<Parameter>

Description

<mode>

0

Extended format disabled (default)

1

Extended format enabled

<serv>

Type of outgoing data calls:
ASYNC - Asynchronous transparent
SYNC - Synchronous transparent
REL ASYNC - Asynchronous non-transparent
REL SYNC - Synchronous non-transparent