&D, Circuit 108 Behavior

This command determines how the G24-L responds when the DTR (Data Terminal Ready) status
is changed from ON to OFF during the online data state. The DTR is an input line that indicates
that the terminal is ready.

The DTR line must be active (low) in order for the G24-L to recognize the terminal. This signal is
raised by the terminal when a process activates the serial port. If the DTR is not used by the
application, it should connect this line to ground (DTR active). The default value is active (low).

The following table shows the &D parameters.

Example

AT&D?

&D: 2

OK

AT&D1

OK

Command Type

Syntax

Response/Action

Set

AT&D<param>

OK

Read

AT&D?

&D:<param>

Test

AT&D=?

&D:(list of supported <param>s)

Table 3-89: &D Parameters

<Parameter>

Description

<param>

The G24-L’s reaction when the DTR status is changed from ON to OFF.
In CSD calls:
0,4

Ignores DTR changes

1

Switches the CSD call to asynchronous command mode (the call remains

connected)
2,3

Disconnects the call and returns to the command mode

In GPRS calls:
0,4

Ignores DTR changes

1-3

Deactivates the GPRS and returns to command mode

The default value is 2.