Configuring web authentication, Figure 3-65, Web authentication configuration – LevelOne FGL-2870 User Manual

Page 166

Advertising
background image

Configuring the Switch

3-112

3

Configuring Web Authentication

Web authentication is configured on a per-port basis, however there are four
configurable parameters that apply globally to all ports on the switch.

Command Attributes
• System Authentication Control –
Enables Web Authentication for the switch.

(Default: Disabled)

• Session Timeout – Configures how long an authenticated session stays active

before it must re-authenticate itself. (Default: 3600 seconds; Range: 300-3600
seconds)

• Quiet Period – Configures how long a host must wait to attempt authentication

again after it has exceeded the maximum allowable failed login attempts.
(Range: 1-180 seconds; Default: 60 seconds)

• Login Attempts – Configures the amount of times a supplicant may attempt and

fail authentication before it must wait the configured quiet period. (Range: 1-3
attempts; Default: 3 attempts)

Web – Click Security, Web Authentication, Configuration.

Figure 3-65 Web Authentication Configuration

CLI – This example globally enables the system authentication control, configures
the session timeout, quiet period and login attempts, and displays the configured
global parameters.

Console(config)#mac-authentication reauth-time 3000

4-164

Console(config)#web-auth system-auth-control

4-175

Console(config)#web-auth session-timeout 1800

4-174

Console(config)#web-auth quiet-period 20

4-174

Console(config)#web-auth login-attempts 2

4-173

Console(config)#end
Console#show web-auth

4-177

Global Web-Auth Parameters

System Auth Control : Enabled
Session Timeout : 1800
Quiet Period : 20
Max Login Attempts : 2
Console#