Snmp-server host – LevelOne FGL-2870 User Manual

Page 458

Advertising
background image

Command Line Interface

4-92

4

snmp-server host

This command specifies the recipient of a Simple Network Management Protocol
notification operation. Use the no form to remove the specified host.

Syntax

snmp-server host host-addr [inform [retry retries | timeout seconds]]

community-string [version {1 | 2c | 3 {auth | noauth | priv} [udp-port port]}

no snmp-server host host-addr

host-addr - Internet address of the host (the targeted recipient).

(Maximum host addresses: 5 trap destination IP address entries)

inform - Notifications are sent as inform messages. Note that this option is

only available for version 2c and 3 hosts. (Default: traps are used)
- retries - The maximum number of times to resend an inform message if

the recipient does not acknowledge receipt. (Range: 0-255; Default: 3)

- seconds - The number of seconds to wait for an acknowledgment before

resending an inform message. (Range: 0-2147483647 centiseconds;
Default: 1500 centiseconds)

community-string - Password-like community string sent with the

notification operation to SNMP V1 and V2c hosts. Although you can set this
string using the snmp-server host command by itself, we recommend that
you define this string using the snmp-server community command prior
to using the snmp-server host command.
(Maximum length: 32 characters)

version - Specifies whether to send notifications as SNMP Version 1, 2c or

3 traps. (Range: 1, 2c, 3; Default: 1)
- auth | noauth | priv - This group uses SNMPv3 with authentication, no

authentication, or with authentication and privacy. See ’Simple Network
Management Protocol" on page 3-49 f
or further information about these
authentication and encryption options.

port - Host UDP port to use. (Range: 1-65535; Default: 162)

Default Setting

• Host Address: None
• Notification Type: Traps
• SNMP Version: 1
• UDP Port: 162

Command Mode

Global Configuration

Command Usage

• If you do not enter an snmp-server host command, no notifications are sent.

In order to configure the switch to send SNMP notifications, you must enter at
least one snmp-server host command. In order to enable multiple hosts, you
must issue a separate snmp-server host command for each host.