Flow sampling commands, Table 4-26, Sflow commands – LevelOne FGL-2870 User Manual

Page 468: Table 4-25, Show snmp user - display description

Advertising
background image

Command Line Interface

4-102

4

Flow Sampling Commands

Flow sampling (sFlow) can be used with a remote sFlow Collector to provide an
accurate, detailed and real-time overview of the types and levels of traffic present on
the network. The sFlow Agent samples 1 out of n packets from all data traversing the
switch, re-encapsulates the samples as sFlow datagrams and transmits them to the
sFlow Collector. This sampling occurs at the internal hardware level where all traffic
is seen, whereas traditional probes only have a partial view of traffic as it is sampled
at the monitored interface. Moreover, the processor and memory load imposed by
the sFlow agent is minimal since local analysis does not take place

Table 4-25 show snmp user - display description

Field

Description

EngineId

String identifying the engine ID.

User Name

Name of user connecting to the SNMP agent.

Authentication Protocol

The authentication protocol used with SNMPv3.

Privacy Protocol

The privacy protocol used with SNMPv3.

Storage Type

The storage type for this entry.

Row Status

The row status of this entry.

SNMP remote user

A user associated with an SNMP engine on a remote device.

Table 4-26 sFlow Commands

Command

Function

Mode

Page

sflow

Enables sFlow globally for the switch

GC

4-103

sflow source

*

* Due to the switch’s hardware design, these commands can only be enabled for specific port groups (1-8, 9-16,

17-24, 25-32, 33-48). However, sampling for each of the Gigabit combination ports (25-28/49-52) can be controlled
individually.

Enables sFlow on the source ports to be monitored

IC

4-103

sflow sample

*

Configures the packet sampling rate

IC

4-104

sflow polling-interval

Configures the interval at which counters are added to the

sample datagram

IC

4-104

sflow owner

Configures the name of the receiver

IC

4-105

sflow timeout

Configures the length of time samples are sent to the

Collector before resetting all sFlow port parameters

IC

4-105

sflow destination

Configures the IP address and UDP port used by the Collector IC

4-106

sflow max-header-size

Configures the maximum size of the sFlow datagram header IC

4-106

sflow max-datagram-size Configures the maximum size of the sFlow datagram payload IC

4-107

show sflow

Shows the global and interface settings for the sFlow process PE

4-107

Advertising