Downloading system software from a server, Figure 3-10, Copy firmware – LevelOne FGL-2870 User Manual

Page 80

Advertising
background image

Configuring the Switch

3-26

3

If a new image is found at the specified location, the following type of messages will
be displayed during bootup.

Downloading System Software from a Server

When downloading run-time code, you can specify the destination file name to
replace the current image, or first download the file using a different name from the
current run-time code file, and then set the new file as the startup file.

Web –Click System, File Management, Copy Operation. Select “tftp to file” as the file
transfer method, enter the IP address of the TFTP server, set the file type to
“opcode,” enter the file name of the software to download, select a file on the switch
to overwrite or specify a new file name, then click Apply. If you replaced the current
firmware used for startup and want to start using the new operation code, reboot the
system via the System/Reset menu.

Figure 3-10 Copy Firmware

.

.

.
Automatic Upgrade is looking for a new image
New image detected: current version 1..1.0; new version 1.3.4.0
Image upgrade in progress
The switch will restart after upgrade succeeds
Downloading new image
Flash programming started
Flash programming completed
The switch will now restart

.

.

.