Sflow sample, Sflow polling-interval – LevelOne FGL-2870 User Manual

Page 470

Advertising
background image

Command Line Interface

4-104

4

sflow sample

This command configures the packet sampling rate. Use the no form to restore the
default rate.

Syntax

sflow sample rate
no sflow sample

rate - The packet sampling rate, or the number of packets out of which one
sample will be taken. (Range: 0-10000000, where 0 disables sampling)

Default Setting

Disabled

Command Mode

Interface Configuration (Ethernet)

Example
This example sets the sample rate to 1 out of every 100 packets.

sflow polling-interval

This command configures the interval at which counters are added to the sample
datagram. Use the no form to restore the default polling interval.

Syntax

sflow polling-interval seconds
no sflow polling-interval

seconds - The interval at which the sFlow process adds counter values to
the sample datagram. (Range: 0-10000000 seconds, where 0 disables this
feature)

Default Setting

Disabled

Command Mode

Interface Configuration (Ethernet)

Example
This example sets the polling interval to 10 seconds.

Console(config)#interface ethernet 1/9
Console(config-if)#sflow sample 100
Console(config-if)#

Console(config)#interface ethernet 1/9
Console(config-if)#sflow polling-interval 10
Console(config-if)#