System Management Commands

4-77

4

Example

Related Commands

show sntp (4-70)

clock summer-time (predefined)

This command configures the summer time (daylight savings time) status and
settings for the switch using predefined configurations for several major regions of
the world. Use the no form to disable summer time.

Syntax

clock summer-time name predefined [australia | europe | new-zealand |

usa]

no clock summer-time

name - Name of the timezone while summer time is in effect, usually an

acronym. (Range: 1-30 characters)

Default Setting

Disabled

Command Mode

Global Configuration

Command Usage

• In some countries or regions, clocks are adjusted through the summer months

so that afternoons have more daylight and mornings have less. This is known
as Summer Time, or Daylight Savings Time (DST). Typically, clocks are
adjusted forward one hour at the start of spring and then adjusted backward
in autumn.

• This command sets the summer-time time relative to the configured time

zone. To specify the time corresponding to your local time when summer time
is in effect, select the predefined summer-time time zone appropriate for your
location, or manually configure summer time if these predefined
configurations do not apply to your location (see clock summer-time (date)
on page 4-76 or clock summer-time (recurring) on page 4-78).

Console(config)#clock summer-time DEST date april 1 2007 23 23 april 23

2007 23 23 60

Console(config)#

Table 4-19 Predefined Summer-Time Parameters

Region

Start Time, Day, Week, & Month

End Time, Day, Week, & Month

Rel. Offset

Australia

00:00:00, Sunday, Week 5 of October 23:59:59, Sunday, Week 5 of March

60 min

Europe

00:00:00, Sunday, Week 5 of March

23:59:59, Sunday, Week 5 of October

60 min