Alarm-related items in group d – Yokogawa Integral Oxygen Analyzer ZR202 User Manual

Page 142

Advertising
background image

IM 11M12A01-05E

10-15

10. Other Functions

Alarm-related Items in Group D

T10.6D.EPS

Code Item

Tuning

Engineering unit Default

setting

D01 Oxygen concentration, high-high

0 to 100

% O

2

100% O

2

alarm setpoint

D02 Oxygen concentration, high-limit

0 to 100

% O

2

100% O

2

alarm setpoint
D03 Oxygen concentration, low-limit

0 to 100

% O

2

0% O

2

alarm setpoint
D04 Oxygen concentration, low-low

0 to 100

% O

2

0% O

2

alarm setpoint
D05

Humidity, high-high alarm setpoint 0 to 100 %H

2

O 100% H

2

O

D06

Humidity, high-alarm setpoint 0 to 100 % H

2

O 100 % H

2

O

D07

Humidity, low-alarm setpoint 0 to 100 % H

2

O 0 % H

2

O

D08

Humidity, low-low alarm setpoint 0 to 100 % H

2

O 0 % H

2

O

D11

Mixing ratio, high-high alarm setpoint 0 to 1 kg/kg 1 kg/kg

D12

Mixing ratio, high-alarm setpoint 0 to 1 kg/kg 1 kg/kg

D13

Mixing ratio, low-alarm setpoint 0 to 1 kg/kg 0 kg/kg

D14

Mixing ratio, low-low alarm setpoint 0 to 1 kg/kg 0 kg/kg

D30 Oxygen concentration alarm

0 to 9.9

% O

2

0.1% O

2

hysteresis

D31

Humidity alarm hysteresis 0 to 9.9 % H

2

O 0.1 % H

2

O

D32

Mixing ratio alarm hysteresis 0 to 0.1 kg/kg 0.001 kg/kg

D33 Delayed alarm action

0 to 255

Seconds 3 seconds

D41 Oxygen concentration,

0: Not detected

Not detected

high-high alarm detection

1: Detection

D42 Oxygen concentration, high-limit

0: Not detected

Not detected

alarm detection

1: Detection

D43 Oxygen concentration, low-limit

0: Not detected

Not detected

alarm detection

1: Detection

D44 Oxygen concentration, low-low

0: Not detected

Not detected

alarm detection

1: Detection

D45

Humidity, high-high alarm detection 0: No detection

No detection

1: Detection

D46

Humidity, high-alarm detection 0: No detection

No detection

1: Detection

D47

Humidity, low-alarm detection 0: No detection

No detection

1: Detection

D48

Humidity, low-low alarm detection 0: No detection

No detection

1: Detection

D51

Mix ratio, high-high alarm 0: No detection

No detection

1: Detection

D52

Mix ratio, high-alarm detection 0: No detection

No detection

1: Detection

D53

Mix ratio, low-alarm

0: No detection

No detection

1: Detection

D54

Mix ratio, low-low alarm detection 0: No detection

No detection

1: Detection