Table 7. three-component analyzer (co, Co + ch, And no + so – Yokogawa IR200 User Manual

Page 91: Table 4: two-component analyzer (co, And ch, Table 8: o, Table 6. two-component analyzer (no and co)

Advertising
background image

9 - 8

IM 11G02M01-01E

Table 7. Three-component analyzer (CO

2

+ CO + CH

4

and NO + SO

2

+ CO)

See Table 4 for CO

2

+ CH

4

measurement of three-component analyzer (CO

2

+ CO + CH

4

) and Table 5 for NO +

SO

2

measurement of three-component analyzer (NO + SO

2

+ CO). See Table 1 for CO measurement.

Table 4: Two-component analyzer (CO

2

and CH

4

)

Table 8: O

2

analyzer

Table 5. Two-component analyzer (NO and SO

2

)

SO

2

E

0

Ϫ

500ppm

B

C

F

0

Ϫ

1000ppm

0

Ϫ

2000ppm

0

Ϫ

5000ppm

D

E

0

Ϫ

500ppm

F

0

Ϫ

1000ppm

NO

0

Ϫ

2000ppm

B

C

D

0

Ϫ

2500ppm

0

Ϫ

2500ppm

0

Ϫ

5000ppm

1st component
(NO),1st range

2nd component (SO

2

), 1st range

:Two components measurable range. 1st component ; NO, 2nd component ; SO

2

ء

1st range (low range) must meet the combination in above table.

2nd range, both NO and

SO

2

measurements are up to 5 times of the 1st range,

and 2nd max. range is 0 to 5000ppm.

T05-1

Table 6. Two-component analyzer (NO and CO)

1st component
(NO),1st range

2nd component (CO), 1st range

CO

E

0

Ϫ

500ppm

B

C

F

0

Ϫ

1000ppm

0

Ϫ

2000ppm

0

Ϫ

5000ppm

D

E

0

Ϫ

500ppm

F

0

Ϫ

1000ppm

NO

0

Ϫ

2000ppm

B

C

D

0

Ϫ

2500ppm

0

Ϫ

2500ppm

0

Ϫ

200ppm

A

G

0

Ϫ

1%

Ϫ

0

Ϫ

5000ppm

:Two components measurable range. 1st component ; NO, 2nd component ; CO

ء

1st range (low range) must meet the combination in above table.

2nd range, both NO and CO measurements are up to 5 times of the 1st range.
2nd max. range of NO

is 0 to 5000ppm.

2nd max. range of CO

2

is 0 to 1%.

T05-1

2nd range

1st range

1

2

0

Ϫ

10%

3

0

Ϫ

25%

4

0

Ϫ

50%

5

0

Ϫ

100%

0

Ϫ

5%

2 0

Ϫ

10%

3 0

Ϫ

25%

4 0

Ϫ

50%

5

: Built-in O

2

analyzer measurable range,

: External zirconia type O

2

analyzer (in this case, Yokogawa

Ј

s ZX8D Style C)

measurable range

ء

O

2

analyzer is selectable indifferently to combination with other components.

0

Ϫ

100%

T09.EPS

Ϫ

Ϫ

Ϫ

Ϫ

Ϫ

Ϫ

Ϫ

Ϫ

Ϫ

Ϫ

1st component
(CO

2

),1st range

2nd component (CH

4

), 1st range

CH

4

F

0 – 5000ppm

G

0 – 1%

E

0 – 2500ppm

D

0 – 2000ppm

C

0 – 1000ppm

–––

–––

–––

–––

–––

–––

–––

–––

–––

–––

–––

–––

–––

–––

H

0– 2%

K

0 – 5%

L

0 – 10%

M

0 – 20%

R

0 – 50%

T

0 – 100%

D 0 – 2000ppm

E 0 – 2500ppm

F 0 to 5000ppm

G

: Available as single range, : 2 ranges of 2 and 2.5 times each range available

CO

2

0 – 1%

H 0 – 2%

K 0 – 5%

–––

–––

–––

–––

–––

–––

–––

–––

–––

–––

–––

L 0 – 10%

M 0 – 20%

R 0 – 50%

T 0 – 100%

P

0 – 25%

T08.EPS