Malfunction group 3 ć Regulation error

CPX error group 103 (CPX−MMI: [Control error] )

No.

Message

Cause/description

Error handling

Type

1)

30

Timeout: Target value not
reached

2)

Obstacle in the positionĆ
ing range (position conĆ
troller only).

·

Remove the obstacle
or correct the target
position.

Error
level: F1
Reset: R

Compressed air is not
sufficient.

·

Check the supply
pressure and tubing
connections.
Configure error 50 as
an error.

Very high friction or irĆ
regular friction (position
controller only).

·

Increase controller
amplification.

Mechanical backlash
(position controller only)

·

Check the installaĆ
tion: Check mass,
stability, guides,
backlash, repeat
identification.

System not optimally
configured.

·

Valve, mass, mountĆ
ing position, supply
pressure, increase
timeout time, inĆ
crease tolerance.

Changed system behavĆ
iour (position controller
only).

·

Repeat identification.

1)

For the error level and reset type, see section 5.2.3.

2)

The drive did not reach the target tolerance in time. (MC monitoring). Record chaining is cancelled.