A.1 cmax technical data, Cmax technical data – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 165

Advertising
background image

A. Technical appendix

A−3

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

A.1

CMAX technical data

CMAX, general

General technical data

see CPX system manual P.BE−CPX−SYS−...

Product weight (with CPX−GE−EV−S)

Approx. 240 g

Protection class as per EN 60 529, completely
installed, plug connector inserted or provided
with protective cap

IP 65

Protection against electric shock
(protection from direct and indirect contact as
per IEC/DIN EN 60204−1)

By means of PELV power circuit
(Protected Extra−Low Voltage)

Module code (CPX−specific)

176

Module identifier (in the handheld unit)

CMAX−C1−1

Positioning module CMAX−C1−1

Tab. A/1: General technical data

CMAX power supply

Operating voltage Ă/Ăload voltage
The following special features apply:
Ĉ Load voltage range for valves (U

VAL

)

see CPX system description P.BE−CPX−SYS−...

20 ... 30 V

CMAX current consumption
Ĉ From operating power supply

Electronics/sensors (U

EL/SEN

)

Ĉ of load voltage supply for valves (U

VAL

)

typically 200 mA at 24 V (see section 3.4.1),
max. 300 mA
typically 1 A ... 2 A at 24 V (see section 3.4.1),
max. 2.5 A

Galvanic isolation
Ĉ between the operating voltage supply for the

electronics/sensors (U

EL/SEN

) and the load

voltage supply for the valves (U

VAL

)

No

Power failure bridging time

10 ms (for systems with the DGCI, a power
dropout > 1 ms causes an error E85)

Tab. A/2: Technical data for power supply

Advertising