3 air reservoir (optional), 4 vpwp proportional directional control valve, Air reservoir (optional) – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 55: Vpwp proportional directional control valve, Section 2.6.3, Section 2.6.4

Advertising
background image

2. Fitting and pneumatic installation

2−25

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

2.6.3

Air reservoir (optional)

If the positioning behaviour does not conform to your requireĆ
ments, and if you ascertain fluctuations in pressure of over
1 bar at the measuring point, then proceed as follows:

·

Install an air reservoir (e.g. type VZS−...−B) between the
filter regulator and the proportional directional control
valve.

This way, you can reduce pressure fluctuations during posiĆ
tioning. You can compensate for slight excesses in the perĆ
missible pressure fluctuation by using supply tubing with a
larger cross section.

Reservoir volume

The reservoir volume should be at least four times as large
as the volume of the drive used.
V

P

= 4 * V

Z

V

P

= buffer volume

V

Z

=

cylinder volume
(Linear drives: V

Z

= r

2

*

ð* L

Z

)

L

Z

=

cylinder stroke length

r =

1/2 * cylinder diameter

2.6.4

VPWP proportional directional control valve

Arrange the tubing between the valve (VPWP) and the drive
symmetrically.

Recommendation for linear drives and drives with piston rod:
tubing length = cylinder length

Fig. 2/10 shows a schematic diagram of the tubing of a cylinĆ
der (example) with the VPWP.

Advertising