4. Commissioning

4−20

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

4.5.3

Controlling the CMAX in direct operating mode

I/O data: Direct mode

Data

Byte 1

Byte 2

Byte 3

Byte 4

Byte 5

Byte 6

Byte 7

Byte 8

O data

CCON

CPOS

CDIR

Secondary
setpoint

Primary setpoint
(position, force)

I data

SCON

SPOS

SDIR

Secondary
actual
value

Primary actual value
(actual position, actual force)

Allocation of the control bytes (overview)

CCON
Byte 1

B7
OPM2

B6
OPM1

B5
LOCK

B4
ć

B3
RESET

B2
BRAKE

B1
STOP

B0
ENABLE

y

To select the operatĆ
ing mode, see
Tab. 4/3

Software
access
blocked

ć

AcknowĆ
ledge
malfuncĆ
tion

Release
brake

Stop

Enable
drive

CPOS
Byte 2

B7
ć

B6
CLEAR

B5
TEACH

B4
JOGN

B3
JOGP

B2
HOM

B1
START

B0
HOLD

y

ć

ć

Teach
value

Jog,
negative

Jog, posiĆ
tive

Start
homing

Start
positionĆ
ing job

ć

CDIR
Byte 3

B7
ć

B6
FAST

B5
XLIM

B4
VLIM

B3
CONT

B2
COM2

B1
COM1

B0
ABS

y

ć

Exact
stop, fast
stop

DeactiĆ
vate
stroke
limit

Speed
limit reĆ
ached

Tracking
mode

Control
mode 2
(profile)

Control
mode 1
(position,
force)

Absolute
/relative

SecondĆ
ary setĆ
point

Byte 4: Setpoint value, depending on the control mode and FHPP setting (PNU 523)
Ĉ Speed in percentage of the set value (PNU 540)
Ĉ Force ramp in percentage of the set value (PNU 550)
Ĉ Mass in percentage of the set value (PNU 544 or PNU 551).

Primary
setpoint

Byte 5 ... 8: Setpoint value of the position or force in the configured system of units,
depending on the control mode.