3. Electrical installation

3−13

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

3.4.1

Determining the current consumption

The current consumption of a CMAX system depends on the
number and type of the modules connected to the axis interĆ
face.

Recommendation:

·

Use a closed−loop regulated power supply.

·

When selecting the power supply unit, check that it proĆ
vides a sufficient output. Calculate the total current conĆ
sumption, if necessary.

Calculations

Tab. 3/10 and Tab. 3/11 show the current consumption for a
positioning system.

Observe the instructions on selecting the power supply unit
in the CPX system description.

CMAX current consumption from U

EL/SEN

of the

CPX terminal

Typical current consumption

200 mA

Maximum current consumption

300 mA

Tab. 3/10: Current consumption via U

EL/SEN

of the

CPX terminal

Current consumption from U

VAL

of the CPX terminal

Typical current consumption for the VPWP valve

1 A

Maximum current consumption for the VPWP voltage
output

0.5 A

Max. current consumption for the digital VPWP output
(clamping unit/brake)

0.5 A

Maximum total current consumption

2.5 A

Tab. 3/11: Current consumption from U

VAL

of the

CPX terminal