5. Diagnostics and error handling

5−20

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

Malfunction group 4 ć System error A

CPX error group 104 (CPX−MMI: [System error A] )

Continued

No.

Message

Cause/description

Error handling

Type

1)

44

Teaching not possible

2)

Teaching (falling edge at
CPOS.TEACH) was trigĆ
gered accidentally due to
breaking a connection or
switching off the control.

·

Only activate
CPOS.TEACH = 1 (preĆ
pare teaching) directly
before the teaching
operation. Always end
teaching immediately.

Error
level: F1
Reset: R

Teaching is not possible
in direct mode.

·

Change operating
mode.

Teaching during active
commissioning function
not possible.

·

End commissioning
function first.

In commissioning operĆ
ating mode, the teaching
target in parameter 1 is
invalid.

·

Correct parameter 1.

Without a reference,
teaching is not possible.

·

Before teaching,
carry out homing.

Lower software end
position is greater
than/equal to the
upper software end
position for teaching
the software end posiĆ
tion in commissioning
operating mode. It is
not accepted.

·

First teach the upper
software end posiĆ
tion.

·

Correct the teaching
position.

Continued ...

Upper software end
position is less than/
equal to the lower softĆ
ware end position for
teaching the software
end position in commisĆ
sioning operating mode.
It is not accepted.

·

First teach the lower
software end posiĆ
tion.

·

Correct the teaching
position.

1)

For the error level and reset type, see section 5.2.3.

2)

For an exact cause, see the diagnostic memory.

Advertising