5. Diagnostics and error handling

5−33

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

5.3.4

LEDs on the sensor interface

LEDs on the CASM−S−D2−R3

LED S1

LED S2

Status

CMAX error:

Green

Off

Ready for operation without errors.

ć

Green

Red

Initialising via CAN completed.

ć

Flashes green

Red

24 V present.

ć

Off

Off

24 V not available.

E80

Green

Flashes red
once

Error: Sensor error (supply voltage < 12 V for longer than
15 ms).

E82

Green

Flashes red
twice

Error: Sensor error (cable break in sensor cable or elecĆ
trical end position reached).

E87

Green

Flashes red
3 times

Error: Supply voltage (< 17 V for longer than 15 ms).

E85

Green

Flashes red
4 times

Error: Communication error (Bus Off" status).

E80

LEDs on the CASM−S−D3−R7

LED S1

LED S2

Status

CMAX error:

Green

Off

Ready for operation without errors.

ć

Green

Red

Initialising via CAN completed.

ć

Flashes green

Red

24 V present.

ć

Flashes green

Off

Not yet referenced.

ć (E10)

Off

Off

24 V unavailable.

E80

Green

Flashes red
once

Error: Sensor error.

E82

Green

Flashes red
twice

Error: Sensor cable (cable break in the sensor cable).

E87

Green

Flashes red
3 times

Error: Supply voltage (< 17 V for longer than 15 ms).

E85

Green

Flashes red
4 times

Error: Communication error (Bus Off" status).

E80