A central (shared) power supply (fig. 3/1), Electrical installation 3−15 – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 75

Advertising
background image

3. Electrical installation

3−15

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

Basic information on the power supply concept of the
CPX terminal can be found in the CPX system description.

A few examples can be found in Fig. 3/1, Fig. 3/2 and
Fig. 3/3.

A central (shared) power supply (Fig. 3/1)

In the example, the entire CPX terminal and the CMAX
positioning system are provided with power via the system
supply.

24ĂV

VAL

0ĂV

VAL

24ĂV

OUT

0ĂV

OUT

0ĂV

EL/SEN

1

1 2 34

Schematic representation:

8DI

8DI

4DO

CMAX

8 A

8 A

MPA

24ĂV

EL/SEN

1

Interlinking block with system supply (supplies the CMAX and the MPA
pneumatics)

Fig. 3/1:

Common power supply (example)

Advertising