Malfunction group 4 ć System error A

CPX error group 104 (CPX−MMI: [System error A] )

No.

Message

Cause/description

Error handling

Type

1)

40

Invalid control mode
with force control

Force control set for
DSMI.

·

DSMI cannot execute
force control comĆ
mands.

Error
level: F1
Reset: R

Impermissible control
mode set in RCB1 or
CDIR.

·

Correct RCB1 or CDIR.

41

Positioning mode ’RelaĆ
tive’ with tracking mode
not allowed

Relative bit
(CDIR.ABS=1) set in
tracking mode.

·

Continuous setpoint
specification may
only be done absoĆ
lutely.

Error
level: F1
Reset: R

42

Reserved control bits set

Reserved and unused
bit set in CCON, CPOS or
CDIR is set.

·

Check CCON, CPOS
and CDIR and correct.

Error
level: W
Reset: F

43

No periphery available
or communication of
axis string disturbed

While initialising the
axis string, neither a
valve nor a displaceĆ
ment encoder was
found.

·

Check the installation

Error
level: F2
Reset: N

Communication disĆ
turbed, e.g. by impermisĆ
sible or damaged comĆ
ponents in the axis
string.

·

Check installation
and exchange com−
ponents, if necessary

Communication with the
valve and displacement
encoder is disturbed.

·

Check lines and comĆ
ponents.

1)

For the error level and reset type, see section 5.2.3.