3 leds on the vpwp, Leds on the vpwp, Diagnostics and error handling 5−32 – Festo Контроллер позиционирования CPX-CMAX User Manual

Page 154: Power ć vpwp logic supply, Error ć vpwp error, Pl ć vpwp load supply

Advertising
background image

5. Diagnostics and error handling

5−32

Festo P.BE−CPX−CMA X−SYS−EN en 0908NH

5.3.3

LEDs on the VPWP

Power ć VPWP logic supply

LED (green)

Sequence

Status

LED
illuminated

ON

OFF

24 V logic supply is present.

LED is off

ON

OFF

VPWP logic supply is not available.
CMAX error: E60

Error ć VPWP error

LED (red)

Sequence

Status

LED is off

ON

OFF

No error.

LED flashes

ON

OFF

Warning:
Ĉ Switch−off temperature almost reached
Ĉ Logic supply lies below 17 V
CMAX error/warning: W68 or E65

LED
illuminated

ON

OFF

Error

1)

CMAX error: E61, E62, E63, E66 or E67

1)

For a message about CMAX error, see section 5.2.4, malfunction group 6.

PL ć VPWP load supply

LED (yellow)

Sequence

Status

LED
illuminated

ON

OFF

24 V VPWP load supply is present

LED is off

ON

OFF

VPWP load supply is not present
or there is an error.
CMAX error: E64

Advertising