Konica Minolta bizhub PRESS C8000e User Manual

Page 364

Advertising
background image

bizhub PRESS C8000

10-56

10.9

[03 Administrator Setting] - [01 System Setting]

10

1

Follow the procedure on page 10-2 to display the Administrator Setting Menu Screen.

2

Press [01 System Setting], [05 Expert Adjustment], [07 Quality Adjustment], and [03 Printer Gamma
Sensor Adj.] in sequence.

The Printer Gamma Sensor Adjustment Screen will be displayed.

3

Select the screen to be adjusted.

% The screens provided here are the same as those provided in the Printer Gamma Offset Adjustment.
% To clear the colorimetric data currently set on the machine and restore the factory default data,

press [Reset Adj. data]. Press [Yes] on the dialog. Or, press [No] to cancel resetting the data.

4

Press [Print Mode].

The Print Mode Screen will be displayed.

5

Select A4

v paper tray, then press Start on the control panel.

A test pattern will be output, and the Printer Gamma Sensor Adjustment Screen will be restored auto-
matically.

6

Place the test pattern on the original glass.

% Position the test pattern [1] face down, with green arrow [2] pointing at the left side.
% Carefully align the test pattern [1] to the vertical original size guide [3] and horizontal original size

guide [4] on the original glass.

% Place about 10 sheets of blank copy paper on top of the test pattern [1].
% Close the ADF.

Advertising