Communication manual 8400 motec CANopen

Implemented CANopen objects

I-1A00 - TPDO1 mapping parameter

Object I-1A00 serves to send parameter data as TPDO1.

[13-16] Data telegram assignment

IEC 61131 process data words are mapped. Only whole bytes can be mapped (1 byte/

mapping entry).

I-1A01 - TPDO2 mapping parameter

Object I-1A01 serves to send parameter data as TPDO2.

For data telegram assignment, see object

I-1A00

.

Index:

I-1A00

Name:

TPDO1 mapping parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Number of mapped application

objects in PDO

0

0

8 rw

U8

1 ... 4: Application object 1 ... 4

0

0

4294967295 rw

U32

Subindex

Meaning

0

Number of mapped objects

1 ... 4

Mapping entries 1 ... 4 for TPDO1

• The 4th mapping entry is used for the static mapping. For this, no value is

available.

8th byte

7th byte

6th byte

5th byte

Data 4

Data 3

Data 2

Data 1

Bit 31 ... bit 16

Bit 15 ... bit 8

Bit 7 ... bit 0

Index

Subindex

Length

Index:

I-1A01

Name:

TPDO2 mapping parameter

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Number of mapped application

objects in PDO

0

0

8 rw

U8

1 ... 4: Application object 1 ... 4

0

0

4294967295 rw

U32

Subindex

Meaning

0

Number of mapped objects

1 ... 4

Mapping entries 1 ... 4 for TPDO2

• The 4th mapping entry is used for the static mapping. For this, no value is