C00347 | can status heartbeat producer, C00349 | can setting, dip switch, Is displayed in – Lenze E84DGFCC User Manual

Page 78: C00349, C00347/1...n, Communication manual 8400 motec canopen

Advertising
background image

Communication manual 8400 motec CANopen

Parameter reference

Parameters for CANopen communication

78

L

EDS84DMOTCAN EN 3.0 - 11/2011

C00347

C00349

Parameter | Name:

C00347 | CAN status HeartBeat producer

Data type: UNSIGNED_8

Index: 24228

d

= 5EA4

h

Display of the heartbeat producer's CAN status



Heartbeat protocol ( 69)

Selection list

0 Boot-up
4 Stopped
5 Operational

127 Pre-operational
250 Failed
255 NoResponse

Subcodes

Info

C00347/1

Status node 1

;

Read access … Write access … CINH … PLC-STOP ; No transfer … PDO_MAP_RX … PDO_MAP_TX ; COM … MOT

Parameter | Name:

C00349 | CAN setting, DIP switch

Data type: UNSIGNED_16

Index: 24226

d

= 5EA2

h

Display of the DIP switch setting at the last mains connection



Possible settings via DIP switch ( 32)

Display area

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Bit 0 Node address 1
Bit 1 Node address 2
Bit 2 Node address 4
Bit 3 Node address 8
Bit 4 Node address 16
Bit 5 Node address 32
Bit 6 Node address 64
Bit 7 Baud rate 1
Bit 8 Baud rate 2
Bit 9 Baud rate 4

Bit 10 Reserved

... ...

Bit 14 Reserved
Bit 15 Accept DIP switch at 24V-ON

;

Read access … Write access … CINH … PLC-STOP ; No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT