Communication manual 8400 motec CANopen

Parameter reference

Parameters for CANopen communication

C00356

C00357

C00359

Parameter | Name:

C00356 | CAN time settings

Data type: UNSIGNED_16

Index: 24219

d

= 5E9B

h

Different time settings for the CAN interface
Setting range

(min. value | unit | max. value)

0

ms

65000

Subcodes

Lenze setting

Info

C00356/1

3000 ms

CAN delay during status change from "Boot-up" to

"Operational"

C00356/2

0 ms

CAN2_OUT cycle time

C00356/3

0 ms

Reserved

C00356/4

0 ms

CANx_OUT time "Operational" to "First transmission"

C00356/5

0 ms

CAN1_OUT cycle time

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX ; COM … MOT

Parameter | Name:

C00357 | CAN monitoring times

Data type: UNSIGNED_16

Index: 24218

d

= 5E9A

h

Mapping of the RPDO event time (see DS301 V4.02)

• If a non-zero value is entered, the RPDO is expected after the time set has elapsed.

• If the RPDO is not received within the expected time, the response set in

C00593/1...2

is effected.

Setting range

(min. value | unit | max. value)

0

ms

65000

Subcodes

Lenze setting

Info

C00357/1

3000 ms

CAN1_IN monitoring time

C00357/2

3000 ms

CAN2_IN monitoring time

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX ; COM … MOT

Parameter | Name:

C00359 | CAN status

Data type: UNSIGNED_8

Index: 24216

d

= 5E98

h

Display of the CAN status



Communication phases/network management ( 40)

Selection list

(read only)

0 Operational
1 Pre-operational
2 Reserved
3 Reserved
4 BootUp
5 Stopped
6 Reserved
7 Reset

;

Read access … Write access … CINH … PLC-STOP ; No transfer … PDO_MAP_RX … PDO_MAP_TX ; COM … MOT