Monitoring of the RPDOs for data reception

10

Monitoring

10.1

Monitoring of the RPDOs for data reception

RPDO1 and RPDO2 have a parameterisable monitoring time within which the RPDO must

arrive.
The following settings can be made in the »Engineer« under the Monitoring tab:

 Response to "BusOff" (bus system switched off),

C00592/2

 CAN1_IN monitoring time,

C00357/1

 CAN2_IN monitoring time,

C00357/2

 Response to CAN1_IN monitoring,

C00593/1

 Response to CAN2_IN monitoring,

C00593/2

If a monitoring time > 0 ms

(

C00357/1...2

) is entered for CAN1_IN/CAN2_IN, the RPDO

is expected after the set time has expired.
If the RPDO is not received within the monitoring time or with the configured sync, the
response set for the respective RPDO is effected

(

C00593/1...2

).

A monitoring time = 0 ms deactivates the monitoring function.