Commissioning

Configuring the host (master)

6.2

Configuring the host (master)

First you have to configure the host (master) for the communication with the controller.

Defining the user data length

 The CANopen communication unit supports the configuration of max. 8 process data

words (max. 64 bytes).

 The user data length is defined during the initialisation phase of the master.
 The user data lengths for process input data and process output data are the same.

Note!

The CANopen process data objects are designated as seen from the node's view:
• Receive PDO (RPDOx): Process data object received by a node
• Transmit PDO (TPDOx): Process data object sent by a node