Communication-relevant parameters of the operating system

12

Parameter reference

This chapter complements the parameter list and table of attributes in the software

manual and the »Engineer« online help for the Inverter Drive 8400 motec by the

parameters for CANopen communication.

12.1

Communication-relevant parameters of the operating system

This chapter lists communication-relevant parameters of the 8400 motec operating

system in numerically ascending order.

C01501

C01503

Software manual/»Engineer« online help "Inverter Drives 8400 motec"
Here you can find general information on parameters.

Parameter | Name:

C01501 | Resp. to communication error with MCI

Data type: UNSIGNED_8

Index: 23074

d

= 5A22

h

Configuration of monitoring modes for the communication unit
Selection list

0 No Reaction
1 Fault
4 WarningLocked

Subcodes

Lenze setting

Info

C01501/1

1: Fault

Resp. to MCI error 1

• Response to a communication error.

C01501/2

1: Fault

Resp. to MCI error 2

• Response to an incompatible communication unit.

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT

Scaling factor: 1

Parameter | Name:

C01503 | MCI timeout

Data type: UNSIGNED_16

Index: 23072

d

= 5A20

h

Setting range

(min. value | unit | max. value)

0

ms

1000

Subcodes

Lenze setting

Info

C01503/1

200 ms

MCI timeout

;

Read access ; Write access … CINH … PLC STOP … No transfer … COM … MOT