Communication manual 8400 motec CANopen
Commissioning
Settings in the Lenze »Engineer«
34
L
EDS84DMOTCAN EN 3.0 - 11/2011
6.4
Settings in the Lenze »Engineer«
The following settings can be made in the »Engineer« under the Settings tab:
CAN node address
(
)
– The node address can only be parameterised if the node address "0" is set via the DIP
switches.
– A change of the node address will only become effective after a CAN reset node.
CAN node is slave or master
(
)
Deceleration during status change from "Boot-up" to "Operational"
(
Time to the first transmission of CANx_OUT in the "Operational" state
(
)
Save changed settings with the device command C00002/11 (save all parameter sets).