Technical data

General data and operating conditions of the PROFIBUS

13

L

EDS84DPBUS EN 2.0 - 09/2010

3

Technical data

3.1

General data and operating conditions of the PROFIBUS

3.2

Protocol data

Mounting instructions "Inverter Drives 8400 protec"
Here you will find information on general technical data, operating conditions

and rated data of the device.

Area

Values

Communication profile

• PROFIBUS DP-V0 (DRIVECOM)

• PROFIBUS DP-V1 (PROFIdrive)

Communication medium

RS485

Interface

9-pole Sub-D socket or M12 socket

Network topology

• Line (without repeater)

• Tree/line (with repeater)

Node

PROFIBUS slave

Number of slaves

• max. 31 (without repeater)

• max. 125 (with repeater)

Max. cable length

1200 m (depending on the selected baud rate and the cable type used)

PNO identification number

0xE84D

Baud rate for cable type A (EN 50170) 9.6 kbps ... 12 Mbps (automatic detection)

Area

Values

Process data words (PCD)

1 ... 16 words (32 bytes)

PROFIsafe messages

4 words (8 bytes)

Cyclic parameter data channel (DP-

V0)

4 words (8 bytes)

Acyclic parameter data channel (DP-

V1)

Max. 240 bytes

PROFIBUS user data length

1 ... 16 words process data channel + 4 words parameter data channel

(10 ... 40 bytes)