Communication manual 8400 protec profibus – Lenze E84Dxxxx User Manual
Page 72
Advertising
EDS84DPBUS EN 2.0 - 09/2010
L
72
Communication manual 8400 protec PROFIBUS
Diagnostics
Advanced diagnostic message
11 PROFIsafe: Error number of safety option SO20/SO30
• If an error occurs in the safety option, byte 11 (LOW byte) and byte 12 (HIGH byte) contain the
respective error number.
• Please also refer to the documentation of the safety option.
12
13 ... 16 Error code of the Inverter Drive 8400 protec
For the sake of legibility, the error number is displayed in the Logbook and in device code C00165 as
follows: [error type].[error subject number].[error ID]
Structure:
A reserved B error type C error subject D error ID
Byte
Description
2
1
0
3
Bit
16
25
26
31
0
15
29
30
Advertising