3 communication time, Communication time, Communication manual 8400 protec profibus – Lenze E84Dxxxx User Manual

Page 14

Advertising
background image

EDS84DPBUS EN 2.0 - 09/2010

L

14

Communication manual 8400 protec PROFIBUS

Technical data

Communication time

3.3

Communication time

The communication time is the time between the start of a request and the arrival of the

corresponding response.
The communication times in a PROFIBUS network depend on ...

the processing time in the controller;

the transmission delay time (baud rate / telegram length);

the nesting depth of the network.

Processing time in the controller

There are no interdependencies between parameter data and process data.

Data

Processing time

Process data

Approx. 2

ms

+ 0 ... 1 ms

+ 1 ... x ms

update cycle

processing time in the module

application task runtime of the technology application used

(tolerance)

Parameter data

Approx. 30 ms + 20 ms tolerance (typical)

• Some codes may require a longer processing time (see software manual/

»Engineer« online help for Inverter Drives 8400).